Authorized Dealer & Supplier for CD Automation
We are Authorized Dealer, Supplier, Solution Provider of CD Automation, REVO S Thyristor Power Controllers, Silicon Controlled Rectifier (SCR) Power Controllers, REVO C 1PH, REVO C 2PH , REVO C 3PH Revo Connect Universal SCR Power Controllers Single Phases, Two Phases, Three Phases, REVEX 1PH, REVEX 2PH, REVEX 3PH Power Controllers On Demand and our setup is situated in Pune, Maharashtra, India.
1) CD3000S 1PH – From 10A to 90A
|
Technical Specification
- Voltage power supply: 24V min, 480V Max, 600V on request
- Input Signal: SSR , Analog 4÷20mA and 0÷10V is available as an option on units from 15A÷90A included
- Firing: Zero crossing ZC / Burst Firing
- Fan Voltage: Supply 230V ± 15% (110V is available as an option)
- Heater Break Alarm: Discrimination better than 20%. * Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. * Latching alarm plus reset. * Relay output 1A at 230V. * Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button.
- Approvals: EMC; cULus available as an option on basic units
- Mounting: Din rail mounting up to 90A included, bulkhead over 110A, IP20 protection
- Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve
|
2) CD3000S 3PH – From 15A to 90A
Technical Specification
- Voltage power supply: 24V min, 480V Max, 600V on request
- Input Signal: SSR (OFF state ‹1Vdc ON = 4÷30 Vdc) firing.
- Firing: Zero crossing ZC.
- Auxiliary Voltage Supply: 10Va power consumption.
- Fan Voltage: 230V ± 15%.
- Approvals:Comply with EMC; cULus available as an option.
- Mounting: Din rail mounting up to 90A.
- Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)
|
|
3) CD3000S 2PH – From 10A to 90A
|
Technical Specification
- Voltage power supply: 24V min, 480V Max, 600V on request
- Input Signal: SSR (OFF state ‹1Vdc ON = 4÷30 Vdc) is standard up to 90A included. Analog input 4÷20mA and 0÷10V is available from 35A (included) to 90A (included)
- Firing: Zero crossing ZC; Burst Firing 4/8/16 with 4÷20mA or 0÷10V with 12÷24V aux. power supply.
- Fan Voltage: 230V ± 15% standard f(110V on request opt., if current ≥75A).
- Heater Break Alarm: Discrimination better than 20%. * Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. * Latching alarm plus reset. * Relay output 1A at 230V. * Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button.
- Approvals: Comply with EMC; cULus available as an option on basic units.
- Mounting: Din rail mounting up to 90A included.
- Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)g Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)
|
REVO S Thyristor Power Controller
REVO S 1PH
- From 30 up to 800A
- Voltage Range 480V, 600V and 690V
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
REVO S 2PH
- From 30 up to 700A
- Voltage range 480V, 600V and 690V
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
REVO S 3PH
- From 30 up to 700A
- Voltage range 480V, 600V and 690V
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
1) REVO C 1PH – Revo Connect Universal SCR Power Controller Single Phase ( REVO C 1PH )
|
- Phases: 1
- Current Range form 30 to 2100A.
- Voltage Range 480V, 600V and 690V .
- Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
- Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
- Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
- USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- 100 KA: Short Circuit Current rating (SCCR) up to 600V
- cUL / UL and CE + EMC approved
|
2) REVO C 2PH – Revo Connect Universal SCR Power Controller Two Phases ( REVO C 2PH )
- Phases: 2
- Current Range from 30 to 2100A.
- Range di tensione 480V, 600V & 690V.
- Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
- Load type: Normal Resistance, Infrared Short, Medium and Long, Transformar Primary using Delayed Triggering
- Firing mode: Burst Firing , Zero Crossing.
- USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- 100 KA: Short Circuit Current rating (SCCR) up to 600V
- cUL / UL and CE + EMC approved
|
|
3) REVO C 3PH – Revo Connect Universal SCR Power Controller Three Phases
|
Technical Specification
- Phases: 3
- Current Range form 30 to 2100A.
- Voltage Range 480V, 600V and 690V.
- Inputs: 4:20mA , 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
- Firing mode:Burst Firing , Delayed Triggering and Phase Angle with or without Soft Start
- Control Mode: Voltage,Current and Power or V2 and I2 with additional Transfer to VxI
- USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- 100 KA: Short Circuit Current rating (SCCR) up to 600V
- cUL / UL and CE + EMC approved
|
1) REVEX 1PH – The Power Controller On Demand
|
Technical Specification :
- Load type: Normal Resistance, Infrared Short, Medium and Long, Transformer Primary, Cold resistance and SiC elements
- Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
- Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
- Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
- Communication: RS485 port. RTU Modbus® Protocol
- USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- Approvals: Comply with EMC
- Dual Current Limit: For peak and RMS value
Option :
- All options are shown below with the relevant model code
- HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit
|
2) REVEX 2PH – The Power Controller On Demand
Technical Specification
- Load type: Normal Resistance, Infrared Short, Medium and Long waveform
- Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
- Firing mode: Burst Firing, Zero Crossing
- Control Mode: Voltage, Current and Power or V2 and I2
- Communication: RS485 port. RTU Modbus® Protocol
- USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- Approvals: Comply with EMC
- Dual Current Limit: For peak and RMS value
Option
- All options are shown below with the relevant model code
- HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circuit
|
|
3) REVEX 3PH – The Power Controller On Demand
|
Technical Specification
- Load type: Normal Resistance, Infrared Short, Medium and Long Waveform
- Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
- Firing mode: Burst Firing, Zero Crossing
- Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
- Communication: RS485 port. RTU Modbus® Protocol
- USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- Approvals: Comply with EMC
- Dual Current Limit: For peak and RMS value
Option
- All options are shown below with the relevant model code
- HB Alarm to diagnose partial or Total Load Failure and Thyristor Short Circui
|